Welcome to: Electronic protection components factory
Service Hotline
0769-83811196
Current Location:Home > News > Industry News >

fused circuit breaker

文章出处:FUSE manufacturers Author:Yaxun Electronics Popularity: Time:2018-02-02 18:52 【Big Middle Small
Fused circuit breaker - Switching and protective devices - Electrical ...
Fused circuit breaker - Switching and protective devices - Electrical ...
Symbols, identification and other circuit symbols · Conductors and connectors · Passive components · Semiconductors and electron tubes · Generation and conversion · Switching and protective devices · Measuring and signalling devices · Communications engineering · Fluid power: General · Basic symbols · Actuators ...

How Does a Fused Disconnect Switch Differ from a Circuit Breaker?
Overcurrent protective devices, such as fused disconnect switches or circuit breakers, are designed to open or disconnect the circuit when an overload or short-circuit occurs, limiting damage to connected equipment and preventing fires. In many cases, fused disconnect switches and circuit breakers can be used ...

How does a fused disconnect switch and a circuit breaker differ ...
How does a fused disconnect switch and a circuit breaker differ ...
Fusing in a disconnect switch provides over current protection for that specific manual switch and the motor it controls. Circuit breakers provide automated over current protection to protect an electrical circuit. This can protect a number of motors and even have fused disconnects further downstream in the circuit. It's a bit of an ...

Vacuum-fused circuit breakers for low and medium voltage AC trailing ...
Vacuum-fused circuit breakers for low and medium voltage AC trailing cable protection. Abstract: Since the enactment of the Federal Coal Mine Safety Act of 1969, the use of fuses has not been allowed for protection for three phase AC trailing cables in underground coal mines. In 1981 a mining equipment manufacturer ...

service-life evaluations of low-voltage power circuit breakers and ...
service-life evaluations of low-voltage power circuit breakers and ...
600 volt rated circuit. For fused breakers, the 635-volt maximum voltage rating becomes 600 volts to match the voltage rating of the fuses. B. Continuous Current Rating. The continuous current rating of a circuit breaker, isolator switch, load-break switch, switchgear assembly, or motor control center is the number of amperes ...

Low voltage circuit breakers Renewal parts catalog
Type K-Don-600, 800, 1600, 600S, 800S, 1600S, 600M, 800M, 1600M Fused Circuit Breakers. 1. Recommended quantities are as follows: Domestic: One (1) complete set for each ten (10) circuit breakers or fraction thereof installed for each rating. International: One (1) complete set for each five (5) circuit breakers.

CJ3B200 Cordon Integrally Fused ITE ETC / Gould Circuit Breaker
CJ3B200 Cordon Integrally Fused ITE ETC / Gould Circuit Breaker
ETC Cordon Integrally Fused CJ3B200. We are the King of obsolete / reconditioned / used / fully rebuilt and tested / ITE circuit breakers and ships out the same day. A business to business type distributor, not a marketing company that claims to have everything. We offer the lowest prices nationwide for all circuit breakers ...

SECURIT ALARM – Alarm system with fused-in circuit breaker
ECKELT I S E C U R I T A L A R M I Page 1. Product description. SECURIT ALARM – Alarm system with fused-in circuit breaker. Function principle. An electrical circuit breaker is fused into one corner of the inner face of a SECURIT sheet of glass, and connected to an alarm system. Breakage of the glass results in the circuit.

FUSE
FUSE
In electronics and electrical engineering, a fuse is an electrical safety device that operates to provide overcurrent protection of an electrical circuit. Its essential component is a metal wire or strip that melts when too much current flows through it, thereby interrupting the current. It is a sacrificial device; once a fuse has operated it is an open circuit, and it must be replaced or rewired, depending on type.
Fuses have been used as essential safety devices from the early days of electrical engineering. Today there are thousands of different fuse designs which have specific current and voltage ratings, breaking capacity and response times, depending on the application. The time and current operating characteristics of fuses are chosen to provide adequate protection without needless interruption. Wiring regulations usually define a maximum fuse current rating for particular circuits. Short circuits, overloading, mismatched loads, or device failure are the prime reasons for fuse operation.

Thermal fuse
Thermal fuse
Thermal fuse is a cutoff which uses a one-time fusible link. Unlike a thermal switch which may automatically reset itself when the temperature drops, the thermal fuse is more like an electrical fuse: a single-use device that cannot be reset and must be replaced when it fails or is triggered. A thermal fuse is used when the overheating is a result of a rare occurrence, such as failure requiring repair (which would also replace the fuse) or replacement at the end of service life.
One mechanism is a small meltable pellet that holds down a spring. When the pellet melts, the spring is released, separating the contacts and breaking the circuit. The Tamura LE series, NEC Sefuse SF series, Microtemp G4A series, and Hosho Elmwood D series, for example, may use alloy pellets that contain copper, beryllium, and silver to melt at a precise temperature. is a cutoff which uses a one-time fusible link. Unlike a thermal switch which may automatically reset itself when the temperature drops, the thermal fuse is more like an electrical fuse: a single-use device that cannot be reset and must be replaced when it fails or is triggered. A thermal fuse is used when the overheating is a result of a rare occurrence, such as failure requiring repair (which would also replace the fuse) or replacement at the end of service life.
One mechanism is a small meltable pellet that holds down a spring. When the pellet melts, the spring is released, separating the contacts and breaking the circuit. The Tamura LE series, NEC Sefuse SF series, Microtemp G4A series, and Hosho Elmwood D series, for example, may use alloy pellets that contain copper, beryllium, and silver to melt at a precise temperature.

Resettable fuse
Resettable fuse
polymeric PTC device is made up of a non-conductive crystalline organic polymer matrix that is loaded with carbon black particles
[2] to make it conductive. While cool, the polymer is in a crystalline state, with the carbon forced into the regions between crystals, forming many conductive chains. Since it is conductive (the "initial resistance"),
[3] it will pass a current. If too much current is passed through the device the device will begin to heat. As the device heats, the polymer will expand, changing from a crystalline into an amorphous state.
[4] The expansion separates the carbon particles and breaks the conductive pathways, causing the device to heat faster and expand more, further raising the resistance.
[5] This increase in resistance substantially reduces the current in the circuit. A small (leakage) current still flows through the device and is sufficient to maintain the temperature at a level which will keep it in the high resistance state.  Leakage current can range from less than a hundred mA at rated voltage up to a few hundred mA at lower voltages. The device can be said to have latching functionality.[
6] The hold current is the maximum current at which the device is guaranteed not to trip. The trip current is the current at which the device is guaranteed to trip.
[7]When power is removed, the heating due to the leakage current will stop and the PPTC device will cool. As the device cools, it regains its original crystalline structure and returns to a low resistance state where it can hold the current as specified for the device.
[8] This cooling usually takes a few seconds, though a tripped device will retain a slightly higher resistance for hours, slowly approaching the initial resistance value. The resetting will often not take place even if the fault alone has been removed with the power still flowing as the operating current may be above the holding current of the PPTC. The device may not return to its original resistance value; it will most likely stabilize at a significantly higher resistance (up to 4 times initial value). It could take hours, days, weeks or even years for the device to return to a resistance value similar to its original value, if at all.
[9]A PPTC device has a current rating and a voltage rating.

Fuse Holder
Fuse Holder
Automotive and Commercial Vehicle Fuse Holders. Fuseholders for automotive style fuses including MINI, ATO, MAXI, MIDI, MEGA, JCASE and Universal Glass Fuses. Fuseholders are available for In-Line, Bolt-Down, Panel Mount and PCB applications.

Automotive Fuses
Automotive Fuses
Automotive fuses are a class of fuses used to protect the wiring and electrical equipment for vehicles. They are generally rated for circuits no higher than 32 volts direct current, but some types are rated for 42-volt electrical systems. They are occasionally used in non-automotive electrical products.

Relevant Information