Welcome to: Electronic protection components factory
Service Hotline
0769-83811196
Current Location:Home > News > Industry News >

Din Rail Blade Fuse Holder

文章出处:FUSE manufacturers Author:Yaxun Electronics Popularity: Time:2018-01-31 16:35 【Big Middle Small
DIN Rail Blade Fuse Terminal Block | Cartridge Fuse Holders|Screw ...
DIN Rail Blade Fuse Terminal Block | Cartridge Fuse Holders|Screw ...
ASI offers din rail fuse terminal blocks which accept both mini fuse blades and fuse cartridge holders for 5x20mm glass fuses. The mini fuses used with these din rail blade fuse terminal blocks offer a wide range of advantages including ease of insertion and removal, color coding to indicate current rating, and availability ...

Terminal Fuse Blocks | DIN Rail Fuse Holders | ASI - ASI-EZ.com
Terminal blocks for 5x20, 5x25, and 6.3x32 mm fuses; Terminal blocks for ¼x1¼ and 13/32x1½ inch fuses; DIN Rail Blade Fuse Terminal blocks used in low voltage applications; Lever style terminal fuse blocks with or without LED blown fuse indication; Screw Cap terminal fuse blocks for glass fuses; Component holder for ...

ASI HF300GR Blade Fuse Holder Spring Clamp Terminal Block for ...
ASI HF300GR Blade Fuse Holder Spring Clamp Terminal Block for ...
ASI HF300GR is a 6.3 mm wide DIN rail mounted blade fuse holder spring clamp terminal block for the CPF05 fuse holder cartridge. The cartridge holds 5 x 20 mm fuse holders. Fuse holder cartridges are sold separately. The stainless steel spring clamps offer superior resistance to corrosion. It accepts wire gauge 26 to 12 ...

WAGO DIN Rail Mounting Mini-Automotive Fuse Holders with Blown ...
Takes mini-automotive blade fuses; 12V or 24V LED operating voltage; Available with or without LED indicator; 2 types of LED circuit depending on DC voltage polarity; Rated voltage 400V; Nominal current 25A; Cable cross-section 0.2 to 6mm²; Cage clamp connection; Dimensions 85 x 33.5 x 8mm (L x H x W); DIN 35 rail ...

30137: DIN-Rail Mountable 2-Wire 5.2 mm Blade-Type Fuse Holder...
30137: DIN-Rail Mountable 2-Wire 5.2 mm Blade-Type Fuse Holder...
Overview. The 30137 fuse block is used with common Mini-Fit automotive fuses. The 30137 is a two-wire, 5.2-mm blade-type fuse holder. It has one input and one protected output. It can accommodate Mini-Fit automotive-style bladed fuses, up to a maximum of 10 A. Fuse holders are commonly used to fuse an output of a ...

Fuse Terminal Blocks | WAGO - WAGO Corporation
Products | Rail-mount terminal block systems | TOPJOB®S rail-mount terminal blocks | Function terminal blocks | Fuse Terminal Blocks | Products | Rail-mount terminal block systems | TOPJOB®S rail-mount terminal blocks | Function terminal blocks | Fuse Terminal Blocks | Overview. WAGO Logo. Online-Catalog ...

PHOENIX CONTACT | Fuse terminal blocks
PHOENIX CONTACT | Fuse terminal blocks
The easily accessible fuse inserts are easy to use or replace. We offer the right fuse holder for every application: Lever-type fuse terminal block; Fuse terminal block with screw cap; Fuse terminal block for accommodating flat-type fuses. The following fuse terminal blocks can be mounted on a DIN rail: Type G fuses; Midget ...

Circuit Protection SAFELOC HRC Fuse Holders Description Features ...
Fuse Blocks,Holders & Misc. For additional information, visit www.edisonfuse.com. SAFELOC HRC Fuse Holders. For use with HRCI-CB Fuses. Edison. Fuse. Rating. Connection ... accommodate the compact range of offset blade fuse to. CSA C22.2 No. ... direct 35mm DIN rail mounting facility as well as single screw fixing.

FUSE
FUSE
In electronics and electrical engineering, a fuse is an electrical safety device that operates to provide overcurrent protection of an electrical circuit. Its essential component is a metal wire or strip that melts when too much current flows through it, thereby interrupting the current. It is a sacrificial device; once a fuse has operated it is an open circuit, and it must be replaced or rewired, depending on type.
Fuses have been used as essential safety devices from the early days of electrical engineering. Today there are thousands of different fuse designs which have specific current and voltage ratings, breaking capacity and response times, depending on the application. The time and current operating characteristics of fuses are chosen to provide adequate protection without needless interruption. Wiring regulations usually define a maximum fuse current rating for particular circuits. Short circuits, overloading, mismatched loads, or device failure are the prime reasons for fuse operation.

Thermal fuse
Thermal fuse
Thermal fuse is a cutoff which uses a one-time fusible link. Unlike a thermal switch which may automatically reset itself when the temperature drops, the thermal fuse is more like an electrical fuse: a single-use device that cannot be reset and must be replaced when it fails or is triggered. A thermal fuse is used when the overheating is a result of a rare occurrence, such as failure requiring repair (which would also replace the fuse) or replacement at the end of service life.
One mechanism is a small meltable pellet that holds down a spring. When the pellet melts, the spring is released, separating the contacts and breaking the circuit. The Tamura LE series, NEC Sefuse SF series, Microtemp G4A series, and Hosho Elmwood D series, for example, may use alloy pellets that contain copper, beryllium, and silver to melt at a precise temperature. is a cutoff which uses a one-time fusible link. Unlike a thermal switch which may automatically reset itself when the temperature drops, the thermal fuse is more like an electrical fuse: a single-use device that cannot be reset and must be replaced when it fails or is triggered. A thermal fuse is used when the overheating is a result of a rare occurrence, such as failure requiring repair (which would also replace the fuse) or replacement at the end of service life.
One mechanism is a small meltable pellet that holds down a spring. When the pellet melts, the spring is released, separating the contacts and breaking the circuit. The Tamura LE series, NEC Sefuse SF series, Microtemp G4A series, and Hosho Elmwood D series, for example, may use alloy pellets that contain copper, beryllium, and silver to melt at a precise temperature.

Resettable fuse
Resettable fuse
polymeric PTC device is made up of a non-conductive crystalline organic polymer matrix that is loaded with carbon black particles
[2] to make it conductive. While cool, the polymer is in a crystalline state, with the carbon forced into the regions between crystals, forming many conductive chains. Since it is conductive (the "initial resistance"),
[3] it will pass a current. If too much current is passed through the device the device will begin to heat. As the device heats, the polymer will expand, changing from a crystalline into an amorphous state.
[4] The expansion separates the carbon particles and breaks the conductive pathways, causing the device to heat faster and expand more, further raising the resistance.
[5] This increase in resistance substantially reduces the current in the circuit. A small (leakage) current still flows through the device and is sufficient to maintain the temperature at a level which will keep it in the high resistance state.  Leakage current can range from less than a hundred mA at rated voltage up to a few hundred mA at lower voltages. The device can be said to have latching functionality.[
6] The hold current is the maximum current at which the device is guaranteed not to trip. The trip current is the current at which the device is guaranteed to trip.
[7]When power is removed, the heating due to the leakage current will stop and the PPTC device will cool. As the device cools, it regains its original crystalline structure and returns to a low resistance state where it can hold the current as specified for the device.
[8] This cooling usually takes a few seconds, though a tripped device will retain a slightly higher resistance for hours, slowly approaching the initial resistance value. The resetting will often not take place even if the fault alone has been removed with the power still flowing as the operating current may be above the holding current of the PPTC. The device may not return to its original resistance value; it will most likely stabilize at a significantly higher resistance (up to 4 times initial value). It could take hours, days, weeks or even years for the device to return to a resistance value similar to its original value, if at all.
[9]A PPTC device has a current rating and a voltage rating.

Fuse Holder
Fuse Holder
Automotive and Commercial Vehicle Fuse Holders. Fuseholders for automotive style fuses including MINI, ATO, MAXI, MIDI, MEGA, JCASE and Universal Glass Fuses. Fuseholders are available for In-Line, Bolt-Down, Panel Mount and PCB applications.

Automotive Fuses
Automotive Fuses
Automotive fuses are a class of fuses used to protect the wiring and electrical equipment for vehicles. They are generally rated for circuits no higher than 32 volts direct current, but some types are rated for 42-volt electrical systems. They are occasionally used in non-automotive electrical products.

Relevant Information