Welcome to: Electronic protection components factory
Service Hotline
0769-83811196
Current Location:Home > News > Company News >

Fuse Structure

文章出处:FUSE manufacturers Author:Yaxun Electronics Popularity: Time:2018-02-09 12:13 【Big Middle Small
ELECTRICAL FUSE STRUCTURE - WU KUEI-SHENG
ELECTRICAL FUSE STRUCTURE - WU KUEI-SHENG
An electrical fuse structure includes a top conductive pattern having a top fuse and a top fuse extension portion, a bottom conductive pattern having a bottom fuse and a bottom fuse extension portion corresponding to the top fuse extension portion, and a via conductive layer positioned between the top fuse ...

Patent US20090309184 - Structure and method to form e-fuse with ...
An e-fuse structure and method has an anode; a fuse link (a first end of the fuse link is connected to the anode); a cathode (a second end of the fuse link opposite the first end is connected to the cathode); and a silicide layer on the fuse link. The silicide layer has a first silicide region adjacent the anode and a second silicide ...

Opinionated Project Structure · Issue #581 · fuse-box/fuse-box · GitHub
Opinionated Project Structure · Issue #581 · fuse-box/fuse-box · GitHub
All the other web build tools seem to take a configuration-centric or a code-centric approach. I really like how fuse-box instead takes a more convention over configuration/code approach than the others. Having an opinionated project structure would help further this goal, while still allowing users to override ...

Patent US6867441 - Metal fuse structure for saving layout area ...
A fuse structure for a semiconductor device on a substrate includes a fuse having an electrically conductive fuse line of a standard fuse length formed in an electrically conductive layer disposed over the substrate, and a pair of electrically conductive, inwardly bent interconnects formed in a first plurality of electrically ...

Common Fuse Structure - We Suck Less - Steak Under Water
Common Fuse Structure - We Suck Less - Steak Under Water
 Another one that I feel is important to get consistent throughout the Fuse Box is the way a Fuse is built. This is a good page to read first: Creating Fuses on VFXPedia Archive.org. I'll just jot down how mine have been structured so far. There's only two of them, really, so please add your insights to this.

WO/2016/111218 TEMPERATURE FUSE STRUCTURE, AND ...
 A temperature fuse structure 13 disconnects the electrical connection between a first conductive path 14 and a second conductive path 15 that are provided on a substrate 11, wherein the temperature fuse structure is provided with the following: a metal member 17 that is connected to the first conductive ...

ABB IEC Indoor Current Limiting Fuse CEF - Indoor Fuses (Fuses and ...
ABB IEC Indoor Current Limiting Fuse CEF - Indoor Fuses (Fuses and ...
The low power losses make these fuse links specially suitable in compact switchgear and for fuse switch disconnectors combination. The fuse design is based on overload spots that significantly reduce fuse structure temperature during interruption process. Additionally, thanks to last modification of striker pin functionality ...

Fuse structure, fuse and welding machine
The invention discloses a fuse structure, a fuse and a welding machine. The fuse structure comprises a first lead (1), a movable contact (2), an elastic reset element (3), a fuse element, a conductive shell (4), a second lead (5), a fuse storage tank (6), heaters (11) and a pressure valve (7), the pressure valve is capable of ...

FUSE
FUSE
In electronics and electrical engineering, a fuse is an electrical safety device that operates to provide overcurrent protection of an electrical circuit. Its essential component is a metal wire or strip that melts when too much current flows through it, thereby interrupting the current. It is a sacrificial device; once a fuse has operated it is an open circuit, and it must be replaced or rewired, depending on type.
Fuses have been used as essential safety devices from the early days of electrical engineering. Today there are thousands of different fuse designs which have specific current and voltage ratings, breaking capacity and response times, depending on the application. The time and current operating characteristics of fuses are chosen to provide adequate protection without needless interruption. Wiring regulations usually define a maximum fuse current rating for particular circuits. Short circuits, overloading, mismatched loads, or device failure are the prime reasons for fuse operation.

Thermal fuse
Thermal fuse
Thermal fuse is a cutoff which uses a one-time fusible link. Unlike a thermal switch which may automatically reset itself when the temperature drops, the thermal fuse is more like an electrical fuse: a single-use device that cannot be reset and must be replaced when it fails or is triggered. A thermal fuse is used when the overheating is a result of a rare occurrence, such as failure requiring repair (which would also replace the fuse) or replacement at the end of service life.
One mechanism is a small meltable pellet that holds down a spring. When the pellet melts, the spring is released, separating the contacts and breaking the circuit. The Tamura LE series, NEC Sefuse SF series, Microtemp G4A series, and Hosho Elmwood D series, for example, may use alloy pellets that contain copper, beryllium, and silver to melt at a precise temperature. is a cutoff which uses a one-time fusible link. Unlike a thermal switch which may automatically reset itself when the temperature drops, the thermal fuse is more like an electrical fuse: a single-use device that cannot be reset and must be replaced when it fails or is triggered. A thermal fuse is used when the overheating is a result of a rare occurrence, such as failure requiring repair (which would also replace the fuse) or replacement at the end of service life.
One mechanism is a small meltable pellet that holds down a spring. When the pellet melts, the spring is released, separating the contacts and breaking the circuit. The Tamura LE series, NEC Sefuse SF series, Microtemp G4A series, and Hosho Elmwood D series, for example, may use alloy pellets that contain copper, beryllium, and silver to melt at a precise temperature.

Resettable fuse
Resettable fuse
polymeric PTC device is made up of a non-conductive crystalline organic polymer matrix that is loaded with carbon black particles
[2] to make it conductive. While cool, the polymer is in a crystalline state, with the carbon forced into the regions between crystals, forming many conductive chains. Since it is conductive (the "initial resistance"),
[3] it will pass a current. If too much current is passed through the device the device will begin to heat. As the device heats, the polymer will expand, changing from a crystalline into an amorphous state.
[4] The expansion separates the carbon particles and breaks the conductive pathways, causing the device to heat faster and expand more, further raising the resistance.
[5] This increase in resistance substantially reduces the current in the circuit. A small (leakage) current still flows through the device and is sufficient to maintain the temperature at a level which will keep it in the high resistance state.  Leakage current can range from less than a hundred mA at rated voltage up to a few hundred mA at lower voltages. The device can be said to have latching functionality.[
6] The hold current is the maximum current at which the device is guaranteed not to trip. The trip current is the current at which the device is guaranteed to trip.
[7]When power is removed, the heating due to the leakage current will stop and the PPTC device will cool. As the device cools, it regains its original crystalline structure and returns to a low resistance state where it can hold the current as specified for the device.
[8] This cooling usually takes a few seconds, though a tripped device will retain a slightly higher resistance for hours, slowly approaching the initial resistance value. The resetting will often not take place even if the fault alone has been removed with the power still flowing as the operating current may be above the holding current of the PPTC. The device may not return to its original resistance value; it will most likely stabilize at a significantly higher resistance (up to 4 times initial value). It could take hours, days, weeks or even years for the device to return to a resistance value similar to its original value, if at all.
[9]A PPTC device has a current rating and a voltage rating.

Fuse Holder
Fuse Holder
Automotive and Commercial Vehicle Fuse Holders. Fuseholders for automotive style fuses including MINI, ATO, MAXI, MIDI, MEGA, JCASE and Universal Glass Fuses. Fuseholders are available for In-Line, Bolt-Down, Panel Mount and PCB applications.

Automotive Fuses
Automotive Fuses
Automotive fuses are a class of fuses used to protect the wiring and electrical equipment for vehicles. They are generally rated for circuits no higher than 32 volts direct current, but some types are rated for 42-volt electrical systems. They are occasionally used in non-automotive electrical products.

Relevant Information